FILLING AND BLEEDING FLIGHT CONTROL HYDRAULIC SYSTEMS
(Continued)
7-16
5.
In cockpit, set FLT CONTR switch (9) on
HYDRAULIC panel (10) to No. 1 ON.
6.
Slowly cycle cyclic control (11) for 5 minutes.
7.
In cockpit, cycle SYSTEM SEL switch (12) on
AFCS panel (13) from OFF to 1 to OFF five times.
8.
Set SYSTEM SEL switch (12) to 1.
7-99