TM 55-1520-240-23-56-45INSTALL NO. 1 FLIGHT CONTROL HYDRAULIC PUMP DRIVE SHAFT SEAL(Continued)6-45Dry cleaning solvent (E162) isflammable and toxic. It can irritateskin and cause burns. Use only inwell-ventilated area, away from heatand open flame. In case of contact,immediately flush skin or eyes withwater for at least 15 minutes. Getmedical attention for eyes.1.Clean seal retainer (1). Use dry cleaning solvent(E162) and cloths (E120). Wear gloves (E186).Wear Kevlar gloves when handling hotretainer. Hot metal can burn hands.Do not heat retainer over 250ºF(120ºC). Heat can damage metal.2.Heat retainer (1) to 230º to 250ºF (110º to120ºC). Use gun-type heater and pyrometer.Wear Kevlar gloves (E187).Oil (E254) is toxic. It can irritate skinand cause burns. Avoid inhaling. Useonly with adequate ventilation. Avoidcontact with skin, eyes, or clothing.In case of contact, immediately flushskin or eyes for at least 15 minutes.Get medical attention for eyes.3.Coat packing (2) with oil (E254). Install packingin retainer (1).4.Install seal (3) in retainer (1), flat side up. Usealuminum tube.5.Install retaining ring (4).6-147