55.
Position stiffener (25) on cover (2). Align holes
(29).
56.
Apply pressure to stiffener (25). Use shot bags
(14).
57.
Cure adhesive for 24 hours at 70º - 80ºF (21º -
27ºC). Remove shot bags (14).
58.
Install four rivets (17 and 18).
INSPECT
FOLLOW-ON MAINTENANCE:
Refinish repaired area (Task 2-353).
END OF TASK