TM 55-1520-240-23-4
5-82.1
ADJUST BLADE BALANCE WEIGHTS
(Continued)
5-82.1
(5)
Example 2 shows a repair at blade station
300, 23 inches aft of the leading edge.
Weight of repair is between 0.44 and
0.659 pounds. This repair requires 3
tracking weights be shifted from aft to
forward fitting.
e.
Record span weight correction (step c) and
tracking weight correction (step d). Go to
step 6.
5-497