TM 55-1520-240-23-4
5-4
PLACE ROTARY-WING HEAD IN SERVICE
5-4
INITIAL SETUP
Applicable Configurations:
All
Tools:
Aircraft Mechanics Tool Kit, NSN 5180-00-323-4692
Rotor Head Lifting Device (T30)
Hoist
Rotory Head Assembly Adapter (T13)
Materials:
Dry Cleaning Solvent (E162)
Cloths (E120)
Lockwire (E231)
Gloves (E186)
Personnel Required:
Medium Helicopter Repairer (2)
Inspector
References:
Task 1-55
Task 1-56
Task 1-57
Task 5-9
Equipment Condition:
Off Helicopter Task
General Safety Instructions:
Dry cleaning solvent (E162) is
flammable and toxic. It can irritate
skin and cause burns. Use only in
well-ventilated area, away from heat
and open flame. In case of contact,
immediately flush skin or eyes with
water for at least 15 minutes. Get
medical attention for eyes.
5-21