5-13.1
REMOVE VERTICAL HINGE PIN OIL TANK SIGHT INDICATOR
(Continued)
5-13.1
3.
Remove lockwire from sight indicator (7).
Remove sight indicator and packing (8).
4.
Install lower plug (4) and packing (6). Torque
plug to 85 inch-pounds.
5.
Lockwire plug (4) to sight indicator (9). Use
lockwire (E231).
INSPECT
FOLLOW-ON MAINTENANCE:
None
END OF TASK