TM 55-1520-240-23-3
4-138
REMOVE POWER TURBINE CONTROL ACTUATOR
(Continued)
4-138
Do not pinch, crush, kink, or make
sharp bends in fire detection element.
Element can be damaged.
3.
Turn fastener (8) counterclockwise and release
element (9) and bushing (10) from three clamps
(11). Move element to side.
4.
Remove lockwire from four screws (12). Remove
four screws and washers (13).
5.
Remove actuator (14).
FOLLOW-ON MAINTENANCE:
None
END OF TASK
4-451