TM 55-1520-240-23-3
4-102.1
ADJUST GAS PRODUCER CONTROL SYSTEM
(Continued)
4-102.1
Do not adjust locknut on N1 control
box.
12.
If the index mark (6) on pointer (4) is not
approximately centered on EMER band (9) and
pointer is not in contact with mechanical stop
(8), adjust resistor shaft (15) until index mark
(6) on pointer (4) is approximately centered on
EMER band (9) and pointer is in contact with
mechanical stop (8).
NOTE
Turning resistor shaft clockwise
will cause pointer to move toward
mechanical stop. Counterclockwise
adjustment will cause pointer to move
away from mechanical stop.
13.
If dark band (11) on rod (10) is not partially
covered (as illustrated), adjust resistor shaft (15)
until dark band (11) is partially covered.
NOTE
Turning resistor shaft clockwise
will tend to cover band (11).
Counterclockwise adjustment will tend
to uncover band (11).
14.
Have helper check pointer (4) on fuel control (5).
Make sure index mark (6) on pointer is centered
on EMEG band (9). If so, go to step 15. If not,
repeat steps 12, 13, and 14.
NOTE
If proper adjustment cannot be
obtained and gas producer control
box has been changed, refer to TM
55-2840-254-23.
15.
Make sure band (11) on rod (10) is partially
covered. If so, go to step 16. If not, repeat steps
12, 13, and 14.
4-385