TM 55-1520-240-23-1012-31INSTALL CARTRIDGE (SQUIB), FIRE EXTINGUISHER (892868-02)(Continued)12-31NOTEThere are two cartridges (squibs) oneach fire extinguisher (bottle). Bothare installed in same way.1.Install ground washer (1) on cartridge (2).2.Apply grease (E190) to cartridge thread (3).3.Install cartridge (2) in housing (4).4.Torque cartridge (2) to 175 inch-pounds.Be sure to remove shunt. Otherwise,fire bottle won’t discharge when it isneeded.5.Remove wire shunt (5) from electrical terminal(6) and body of cartridge (2).6.Install wire (7), washer (8), screw (9), and twonuts (10) on ground washer (1). Remove tagfrom wire.7.Install wire (11) and nut (10) on terminal (6).Remove tag from wire.INSPECTFOLLOW-ON MAINTENANCE:Perform operational check (TM 55-1520-240-T).END OF TASK12-74