TM 55-1520-240-23-10
15-4
INSTALL AUXILIARY POWER UNIT (APU)
(Continued)
15-4
11.
Operate hoist (25) to remove tension from cable
(22).
12.
Remove bolt (23) and nut (24) to disconnect
cable (22) from links (7).
13.
Unhook tackle block (40) from fitting (41).
14.
Remove bolt (42) and nut (43) to remove lug (44)
from clevis (45). Remove hoist (25).
15.
Slide exhaust duct (46) forward over APU (1).
Check for 0.09 inch minimum gap between duct
(46) and tailcone closure (47.1) before tighting
clamp (47). Tighten clamp (47).
15-23