TM 55-1520-240-23-10
12-2
TEST CENTER WINDSHIELD ANTI-FOGGING ELEMENT
(Continued)
12-2
CENTER WINDSHIELD ANTI-FOGGING ELEMENT
NOTE
Windshield must not be in direct sun
when reading temperature on FAT
thermometer.
10.
Remove screw (1), lockwasher (2), and flat
washer (3) from terminal (13). Disconnect wire
(14).
11.
Measure resistance between terminals (13 and
15). Resistance shall be as listed under step 8
for windshield temperature.
12.
Connect wire (14) to terminal (13). Install flat
washer (3), lockwasher (2), and screw (1).
FOLLOW-ON MAINTENANCE:
None
END OF TASK
12-9