TM 55-1520-240-23-10
13-6.1
ASSEMBLE HEATER (AVIM)
(Continued)
13-6.1
24.
Install rope gasket (29) on flue drain (30).
Permatex (E273) is flammable and
toxic. It can irritate skin and cause
burns. Use only in well-ventilated
area, away from heat and open flame.
In case of contact, immediately flush
skin or eyes with water for at least
15 minutes. Get medical attention
for eyes.
25.
Apply coat of Permatex (E273) to both sides of
gasket (31). Wear gloves (E186).
26.
Position gasket (31) on combustion air
connection (32).
27.
Spread jacket (33) just enough to slide jacket
over flue drain (30) and air connections (32).
28.
Slide jacket (33) over combustion chamber (2).
13-42