TM 55-1520-240-23-1
1-62
MANUAL SERVICE HYDRAULIC SYSTEM RESERVOIR (Continued)
1-62
WARNING
Hydraulic fluid (E199) is toxic. It can
irritate skin and cause burns. Avoid
inhaling. Use only with adequate
ventilation. Avoid contact with skin,
eyes, or clothing. In case of contact,
immediately flush skin or eyes for
at least 15 minutes. Get medical
attention for eyes.
5.
Open cap (6) on fill module (7). Fill with hydraulic
fluid (E199).
6.
Set selector valve (8) on fill module (7) to system
to be filled.
7.
Press and hold button (3) on panel (2). Observe
fluid level on applicable gauge (4 or 5). Make
sure selector switch (1) is set to correct position
if filling flight control system. Operate fill module
pump (9) until gauge (4 or 5) reads FULL.
8.
Observe fluid level gauge (10) while operating
pump (9). Keep gauge full of fluid (E199) at all
times while pumping.
9.
Repeat steps 6 thru 8 for other systems as
required.
10.
Release button (3) on panel (2).
11.
Close cap (6) on fill module (7).
12.
Set fill module selector valve (8) to CL.
FOLLOW-ON MAINTENANCE:
Disconnect battery (Task 1-39).
END OF TASK
Change 3
1-241