• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
REMOVE  TUNNEL FORWARD  CONNECTING  LINKS
INSTALL  TUNNEL FORWARD  CONNECTING  LINKS

TM-55-1520-240-23-9 CH-47D Heilcopter Manual
Page Navigation
  897    898    899    900    901  902  903    904    905    906    907  
TM  55-1520-240-23-9 11-234 REMOVE  TUNNEL FORWARD  CONNECTING LINKS (Continued) 11-234 4. Remove  nut  (7),  two  washers (8),  bolt  (9),  and electrical  lead  ground  wire  (10)  from  clamp  (11). 5. Remove  cotter  pin  (12),  nut (13),  washers  (14), and  bolt (15) from  connecting  links  (1  and  16) and  control  arm  (17). 6. Without    38  ,  if  connecting  link  (1)  is  to  be replaced  remove  clamp  (11) from  link. 7. With   38  , if  connecting  link  (1)  is to  be  replaced, leave  clamp  (11) with  link. 8. Remove  connecting  links  (1  and  16) from  control arm  (17). FOLLOW-ON MAINTENANCE: None END  OF  TASK 11-913