REPAIR  AFT LCT YOKE
REMOVE  AFT LCT YOKE  BEARINGS  (AVIM)

TM-55-1520-240-23-9 CH-47D Heilcopter Manual
Page Navigation
  874    875    876    877    878  879  880    881    882    883    884  
TM  55-1520-240-23-9 11-228 REPAIR  AFT LCT YOKE (Continued) 11-228 1. Clean  yoke  (1).  Use  dry  cleaning  solvent  (E162) and  cloth  (E120).  Wear gloves  (E184.1). INSPECT 2. Measure  depth  of  any  nicks,  scratches  or gouges.  Damage  must not be  greater than  0.060 inch deep. 3. In  critical  areas  (2),  blend  out  nicks,  scratches or gouges  greater than  0.005  inch  deep.   Use abrasive  cloth  (E1).  Do  not  blend  deeper than 0.060  inch.  Blend  radius must  not be  less  than 1  inch. 4. In  non-critical  areas  (3),  blend  out  nicks, scratches  or  gouges greater  than  0.015  inch deep.   Use  abrasive  cloth  (E1).   Do  not  blend deeper than  0.060 inch  or 10 percent of material thickness  whichever is  less.   Blend  radius  must not  be  less  than  1 inch. 5. Clean  yoke  (1).  Use  dry cleaning  solvent (E162). Wear  gloves  (E184.1). Epoxy  primer  (E292.1)  is flammable and  toxic.   It  can  irritate  skin  and cause  burns.  Use  only with  adequate ventilation,  away  from  heat  and open  flame.  Avoid  contact  with  skin, eyes,  or clothing.  In  case  of contact, immediately flush  skin  or eyes  with water  for  at  least 15 minutes.   Get medical  attention  for eyes. 6. Coat blended  areas  with  epoxy primer (E292.1). Wear  gloves  (E184.1). INSPECT FOLLOW-ON MAINTENANCE: None END  OF  TASK 11-889







Western Governors University

Privacy Statement
Press Release
Contact

© Copyright Integrated Publishing, Inc.. All Rights Reserved. Design by Strategico.