TM 55-1520-240-23-9
11-210
INSTALL FORWARD LCT CONNECTING LINK
(Continued)
11-210
Do not use cadmium plated hardware
or tools while working on yoke
assembly. Titanium yoke could be
damaged.
Bushings must be in swashplate and
yoke before installing bolts; otherwise,
damage to components will result.
NOTE
Positive retention bolts are installed
in flight control connections. These
bolts are self-retaining and require a
special nut and torque (Task 1-13).
1.
Remove nuts (1, 2, and 3), washers (4 thru 8),
and bolts (9, 10, 11) from swashplate (12) and
yoke (13).
Antiseize compound (E75) can form
toxic vapors if exposed to flame. Use
only with adequate ventilation, away
from open flame. In case of contact,
immediately flush skin or eyes with
water for at least 15 minutes. Get
medical attention for eyes.
2.
Apply antiseize compound (E75) to bushing (14)
on bolt (9). Keep compound off threads of bolt.
Wear gloves (E184.1).
11-833