TM 55-1520-240-23-9
11-202
REMOVE FORWARD ACTUATOR
(Continued)
11-202
Do not use cadmium plated hardware
or tools while working on yoke
assembly. Titanium yoke could be
damaged.
Do not use chlorinated solvents for
cleaning. Titanium yoke could be
damaged by this solution.
NOTE
Positive retention bolts are installed in
upper controls. Bolts have pawl which
prevents nut or bolt removal unless
pawl is depressed. Refer to Task 1-13.
Attaching bolts, washers, and nuts will
be temporarily installed after removing
actuator and connecting link.
NOTE
If a crack in the connecting link or
yoke is suspected during removal,
refer to TM 1-1520-253-23.
NOTE
If LCT is being removed for
replacement, rigging check of
replacement actuator may be
performed by temporarily placing
replacement LCT on work platform
and completing Task 11-40.
1.
Remove cotter pin (1), nut (2), washer (3),
and bolt (4) attaching connecting link (5) to
swashplate (6).
11-808