REMOVE  FORWARD  ACTUATOR
REMOVE  FORWARD ACTUATOR (Continued)

TM-55-1520-240-23-9 CH-47D Heilcopter Manual
Page Navigation
  793    794    795    796    797  798  799    800    801    802    803  
TM  55-1520-240-23-9 11-202 REMOVE  FORWARD  ACTUATOR (Continued) 11-202 Do  not  use  cadmium  plated  hardware or  tools  while  working  on  yoke assembly.   Titanium  yoke  could  be damaged. Do  not  use  chlorinated  solvents for cleaning.   Titanium  yoke  could  be damaged  by this  solution. NOTE Positive  retention  bolts  are  installed  in upper controls.  Bolts have  pawl  which prevents nut  or  bolt removal  unless pawl is depressed.  Refer to Task 1-13. Attaching  bolts, washers, and  nuts  will be  temporarily installed  after removing actuator and  connecting  link. NOTE If  a  crack  in  the  connecting  link  or yoke  is  suspected  during  removal, refer  to  TM  1-1520-253-23. NOTE If  LCT  is  being  removed  for replacement,  rigging  check  of replacement  actuator  may  be performed  by  temporarily  placing replacement LCT  on  work  platform and  completing  Task  11-40. 1. Remove  cotter  pin  (1),  nut  (2),  washer (3), and  bolt  (4) attaching  connecting  link  (5)  to swashplate  (6). 11-808