  738    739    740    741    742  743  744    745    746    747    748  
TM  55-1520-240-23-9 11-188 REMOVE  FIRST STAGE MIXING  ASSEMBLY (Continued) 11-188 Do  not  drive  shaft out  of  bellcranks. Damage  to  bellcranks and  bearings will  result. 24. Tag  pitch  input  bellcrank  (6).   Carefully  slide shaft (74)  inboard  until  bellcrank (6) is  released. Remove  bellcrank. 25. Carefully  slide  shaft (74)  out of thrust  bellcrank (33) and  support  (79). 26. Remove  bellcranks  (33  and  44),  and  adapters (80  and  81). 27. Remove  adapter  (80)  from  bellcranks (33  and 44). 28. Remove  adapter (81) from  bellcrank (44). FOLLOW-ON MAINTENANCE: None END  OF  TASK 11-751