REMOVE  THRUST  CCD  ACTUATOR
DISASSEMBLE  THRUST CCD  ACTUATOR  (AVIM)

TM-55-1520-240-23-9 CH-47D Heilcopter Manual
Page Navigation
  624    625    626    627    628  629  630    631    632    633    634  
TM  55-1520-240-23-9 11-154 REMOVE  THRUST CCD  ACTUATOR (Continued) 11-154 1. Tag  and  disconnect  connector  (1) from  thrust CCD actuator  (2). 2. Disconnect spring  (3) from  arm  (4)  of  actuator (2)  (Task  11-131). 3. Remove  cotter  pin  (5), nut  (6), two  washers (7), and  bolt (8) from arm (4).  Disconnect link (9) from arm.  Install  bolt, washers and  nut  loosely in  link. Tie  link away from  actuator.  Use  twine  (E433). 4. Remove  bolt (10) and  washer  (11)  from  stop (12).   Loosen  bolt  (13)  of  stop. 5. Remove  three  bolts  (14) and  washers  (15) from actuator (2).  Remove  actuator.  Lift  inboard  end (16) up  to  release  support  (17) from stop  (12). 6. Remove  lockwire  from  four bolts (18). 7. Remove  four bolts (18) and  washers  (19)  from support (17).  Remove  support from actuator (2). FOLLOW-ON MAINTENANCE: None END  OF  TASK 11-635