TM 55-1520-240-23-9
11-81
INSTALL PILOTS COCKPIT CONTROL ASSEMBLY
(Continued)
11-81
Acetone (E20) can form toxic
vapors if exposed to flame. Use in
well-ventilated area, away from open
flame. In case of contact, immediately
flush skin or eyes with water for
at least 15 minutes. Get medical
attention for eyes.
65.
Clean sealant from flange (97) and inside surface
(98) of access. Use acetone (E20) and cloths
(E120). Wear gloves (E186) and goggles.
66.
Support right housing assembly (99). Remove
strap (100).
Sealant (E336) can irritate skin and
cause burns. Avoid contact with skin,
eyes, and clothing. In case of contact,
immediately flush skin or eyes with
water for at least 15 minutes. Get
medical attention for eyes.
67.
Apply sealant (E336) to both sides of gasket
(101). Install gasket on flange (102). Remove
excess sealant with acetone (E20) and cloths
(E120). Wear gloves (E186) and use goggles.
68.
Tilt housing assembly (99) and position housing
up and inside access (7), lamp (102) aft. Align
housing and access holes (103).
69.
Repeat steps 65 thru 66 for left housing (104),
then go to step 70.
11-427