TM  55-1520-240-23-9 11-66 INSTALL  THRUST  CONTROL (PILOT) (Continued) 11-66 Acetone  (E20)  can  form  toxic vapors  if  exposed  to  flares.   Use  in well-ventilated  area,  away from  open flame.  In  case  of contact,  immediately flush  skin  or  eyes  with  water  for at  least  15  minutes.   Get  medical attention  for eyes. 12. Clean old  sealant from flange  (28) of landing  light housing  assembly  (29).   Use  acetone  (E20) and cloths  (E120).  Clean  old  sealant  from  inside  of flange  (30).   Wear gloves  (E186). Sealant  (E336) can  irritate  skin  and cause  burns.  Avoid  contact  with  skin, eyes,  and  clothing.  In  case  of  contact, immediately  flush  skin  or eyes  with water for  at  least  15 minutes.   Get medical  attention  for eyes. 13. Apply  sealant  (E336) to  both  sides  of  gasket (31).  Install  gasket  on  flange  (28).   Wear gloves (E186). 14. Tilt  housing  assembly (29) to  one  side  and  guide it  up  and  inside  structure  (30).   Make  sure  lamp (32)  is  aft. 15. Connect  electrical lead  (33) to  stud  (34).  Install washer (35)  and  nut  (36). 11-302