TM 55-1520-240-23-9
11-44
RIG PITCH OVERTRAVEL STOP
(Continued)
11-44
9.
Working in passageway, check first stage
bellcrank stop (21). Have helper in cockpit press
switch (9) and move stick (10) aft until bellcrank
(11) just touches stop (21). Hold stick position.
Release switch.
10.
Working through right access (17), measure
and record distance E between stop (22) and
bellcrank (23).
11-188