TM 55-1520-240-23-9
11-41
SWASHPLATE BALL AND SLIDER TRAVEL CHECK
(Continued)
11-41
3.
Working from forward left work platform,
measure and record distance between bottom of
swashplate ball slide (5) and stop (6) on slider
guide (7). Distance must not be less than 3/64
inch. Use a feeler gage.
4.
Press switch (3) on stick (4). Position stick fully
aft. Do not move stick left or right. Release
switch.
5.
Working from aft left work platform, measure and
record distance between bottom of swashplate
ball slider (8) and stop (9) on slider guide (10).
Distance must not be less than 17/64 inch.
11-158