  1184    1185    1186    1187    1188  1189  1190    1191    1192    1193  
TM  55-1520-240-23-9 11-280 AFCS  INTERFACE  TEST (Continued) 11-280 TEST 30 RADAR ALTIMETER SELECT TEST (NO.  1) 186. Set  AECS  SYSTEM  SEL  switch  (1)  to  1  or  2. (System  under  test.) 187. Set METER  SOURCE  switch  (3)  to  DISCRETE MONITOR. 188. Set DISCRETE  SIGNAL  MONITOR  switch  (34) to  SEL  1. 189. Set  SIGNAL  SEL  1  switch  (54)  to  RADAR  ALT ENGAGED. STATUS  B light  (39)  shall  come  on. Read  digital  display (6).  Reading  shall  be  -0.5 to +0.5  VDC. 190. Press RAD  ALT  ENGAGED  switch  (65).  STATUS A  light  (37)  shall  come  on.   Read  digital  display (6).  Reading  shall be  +11.0  to +13.0  VDC. END RADAR  ALTIMETER  SELECT TEST (NO. 1) 11-1203