TM  55-1520-240-23-9 11-280 AFCS  INTERFACE  TEST (Continued) 11-280 Table  11-5 MONITOR  SELECT  FDBK  SWITCH  POSITION ILCA  YAW  SWITCH POSITION SELF FDBK  (VOLTS AC) SUM 1 FDBK (VOLTS AC) SUM 2 FDBK (VOLTS AC) 0 -0.20  TO  +0.20 -0.20  TO  +0.20 -0.20  TO  +0.20 85%  RETR +1.23  to  +1.66 +0.62  to  +0.83 +0.62  to  +0.83 MAX  RETR +1.45  to  +1.96 +0.72  to  +0.98 +0.72  to  +0.98 85%  EXT -1.23  to -1.66 -0.62  to -0.83 -0.62  to -0.83 MAX  EXT -1.45  to -1.96 -0.72  to -0.98 -0.72  to -0.98 Table  11-6 ILCA YAW SWITCH POSITION ILCA MECHANICAL  OUTPUTS ACTUATOR  NO.  1 (UPPER) MECHANICAL OUTPUTS ACTUATOR  NO.  2 (LOWER) 0 Neutral Neutral Neutral 85%  RETR 85%  Retracted 85%  RETR 85%  EXT MAX  RETR Full  Retracted FULL  RETR FULL  EXT 85%  EXT 85%  Extended 85%  EXT 85%  RETR MAX  EXT Full  Extended FULL  EXT FULL  RETR END  YAW  ILCA  AUTHORITY/PHASING  TEST  (BOTH) 11-1178