• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
BENCH  TEST AFCS  CONTROL PANEL (AVIM) (Continued) - TM-55-1520-240-23-9_1062
BENCH TEST AFCS CONTROL PANEL (AVIM) (Continued) DIODE  CHECK

TM-55-1520-240-23-9 CH-47D Heilcopter Manual
Page Navigation
  1026    1027    1028    1029    1030  1031  1032    1033    1034    1035    1036  
TM  55-1520-240-23-9 11-272 BENCH TEST AFCS CONTROL PANEL (AVIM) (Continued) 11-272 TEST  7 PANEL  ILLUMINATION NOTE Perform  preliminary  test  procedure before  test. (Refer  to  TM 55-4920-430-13.) 103. Set  TESTER  POWER  switch  (1) to  ON.  The following  lamps shall  be  on: a. 115V  400  HZ  lamp  (2). b. +28VDC  lamp  (3). c. +5VDC  lamp  (4). d. +15VDC  lamp  (5). e. -15VDC  lamp  (6). 104. Set  AFCS  POWER switches  (7  and  8)  to  ON. The  following  lamps shall  be  on: a. 115V  400  HZ  lamp  (9). b. +28VDC  lamp  (10). c. +5VDC lamp  (11). 105. Check  AFCS  panel  (30).   All  panel  illumination lamps  shall  be  on  and  red  in  color. 106. Set  TESTER  POWER  switch  (1)  and  AFCS POWER switches  (7  and  8)  to  OFF. 107. Disconnect test cable  W4  145G5180-1  (31) from AFCS  panel (30) receptacle  J1  (32). 108. Disconnect test cable  W5  145G5181-1  (33) from AFCS  panel (30) receptacle  J2  (34). END PANEL ILLUMINATION TEST 11-1047







Western Governors University

Privacy Statement
Press Release
Contact

© Copyright Integrated Publishing, Inc.. All Rights Reserved. Design by Strategico.