TM 55-1520-240-23-8
10-102
INSTALL APU FUEL SHUTOFF MANUAL VALVE
10-102
INITIAL SETUP
Applicable Configurations:
All
Tools:
Aircraft Mechanics Tool Kit, NSN 5180-00-323-4692
Materials:
None
Personnel Required:
Medium Helicopter Repairer
Inspector
References:
TM 55-1520-240-23P
General Safety Instructions:
All regulations and instructions
for handling fuels shall be strictly
observed.
1.
Remove caps from valve (1).
2.
Position INLET connector (2) of valve (1) through
hole in bracket (3). Make sure valve handle (4)
is on top.
3.
Install washer (5) and nut (6).
4.
Remove plugs from fuel connectors (7). Connect
two fuel connectors to valve (1).
INSPECT
FOLLOW-ON MAINTENANCE:
Perform APU operational check (TM 55-1520-240-T).
Check for leaks (Task 10-4).
END OF TASK
10-466