TM 55-1520-240-23-8
10-72
INSTALL FORWARD FUEL TANK FUEL LEVEL SHUTOFF VALVE
(Continued)
10-72
NOTE
Procedure is same to install fuel level
shutoff valve in No. 1 or No. 2 fuel
system. Installation of No. 2 (right)
shutoff valve is shown here.
1.
Position tube (1) on shutoff valve (2). Make sure
two hose connections (3) are at top, and tube
points down. Install four bolts (4), washers (5),
and nuts (6).
2.
Position packing (7) on fitting (8). Position fitting
(8) on valve (2). Install four bolts (9) and washers
(10).
3.
Install packing (11) on flange of valve (2).
4.
Remove barrier material and tape from hole in
tank (12). Clean tape residue from tank. Use
cloth (E135) damp with dry cleaning solvent
(E162). Wear gloves (E184.1).
5.
Maneuver fuel valve (2) through hole in tank (12)
with tube (1) pointing down. Connect two hoses
(13) to valve connections (3).
6.
Position flange of valve (2) against tank (12) with
tube (1) pointing down. Install 10 bolts (14) and
washers (15).
10-351