TM  55-1520-240-23-7 9-125.2 REPAIR  OF CAUTION PANEL NVG FILTER (Continued) 9-125.2 REPLACE  SPRING NOTE Procedure  is  same  to  replace  either spring. 8. Drill  out  two  rivets  (7).   Use  a  3/32  inch  drill. Remove  spring  (8) from  support (9). 9. Position  replacement  spring  (8) on  support (9). 10. Install  two  3/32  rivets  (7), countersink at support (9). REPLACE  CUSHION NOTE Procedure  is  same  to  replace  either cushion. 11. Remove  cushion  (10)  from  track  (11).   Use  a utility  knife. 12. Remove  old  sealant.  Use  acetone  (E20).  Wear gloves (E186). 9-502