REMOVE  CAUTION  PANEL NVG FILTER (Continued)
REPAIR  OF CAUTION PANEL NVG FILTER (Continued) - TM-55-1520-240-23-7_886

TM-55-1520-240-23-7 CH-47D Heilcopter Manual
Page Navigation
  845    846    847    848    849  850  851    852    853    854    855  
TM  55-1520-240-23-7 9-125.2 REPAIR  OF CAUTION  PANEL  NVG  FILTER 9-125.2 INITIAL  SETUP Applicable  Configurations: With    17   and  Without   74 Tools: Airframe  Repairer’s Tool  Kit, NSN 5180-00-323-4876 Drill Twist  Drill  Set Utility  Knife Materials: Acetone  (E20) Sealant  (E336) Cloths  (E120) Tape  (E402) Gloves  (E186) Personnel  Required: Aircraft  Structural  Repairer Equipment  Condition: Off  Helicopter  Task General  Safety Instructions: Acetone  (E20) is extremely flammable. It can  be  toxic.   Avoid  inhaling.   Use only with  adequite  ventilation.  Avoid contact  with  skin,  eyes,  or  clothing. Keep  away from  heat,  sparks,  or open flame.  In  case  of contact,  immediately flush  skin  or  eyes  with  water  for at  least  15  minutes.   Get  medical attention  for eyes. NOTE Repair of  the  NVG  caution  panel filter is limited  to  replacement of four  parts: glass, spring, cushion,  and  lock. 9-500