TM  55-1520-240-23-7 9-124.1 LIGHT  LEAK  TEST (Continued) 9-124.1 DOPPLER  SYSTEM  LIGHTS 68. Set  doppler  system  lights  to  ON  (TM 11-1520-240-23).  There  shall  be no  white  light leaks,  displays only.  Lightplate still  green. 69. Set lights  to  OFF. COUNTERMEASURE  SYSTEM  LIGHTS 70. Set countermeasures  system  lights  to ON  (TM 11-1520-240-23).There shall  be  no white  light leaks,  push  button on ALQ-156 only.  Lightplate still  green. 71. Set lights  to  OFF. FLARE  DISPENSER  SYSTEM  LIGHTS 72. Set  flare  dispenser  system  lights  to  ON (TM 11-1520-240-23).  There  shall  be no  white  light leaks. 73. Set  lights  to OFF. PRESS-TO-TEST LIGHTS 74. Close the following circuit  breakers  on  the No. 2  PDP  (1): a. TROOP  JUMP  IT  (79). b. RH  AUX FWD  FUEL  PUMP  (80). c. ENG  NO.  2  START  AND  TEMP  (80.1) (Without   74  ). d. CARGO HOOK  PWR  NORM  (81). 75. Close the following circuit  breakers  on  the No. 1  PDP  (23). a. LH  AUX  FWD  FUEL  PUMP  (82). b. ENG  NO.  1  START  AND  TEMP  (82.1) (Without   74  ). 9-486