TM 55-1520-240-23-7
9-124
ADJUST TROOP JUMP SIGNAL DIMMING RESISTOR
(Continued)
9-124
7.
Connect multimeter (6) to resistor terminal (11)
and aircraft ground (8).
8.
Set Troop JUMP LIGHT switch (2) to RED.
9.
Loosen screw (12) and move slider band (13)
until multimeter (6) indicates 14 to 16 volts.
10.
Tighten screw (12). Disconnect multimeter (6).
11.
Raise panel (5) and install two bolts (3) and
washers (4).
12.
Shut down electrical power.
13.
Disconnect battery.
FOLLOW-ON MAINTENANCE:
Perform operational check (TM 55-1520-240-T).
END OF TASK
9-475