TM 55-1520-240-23-7
9-85.2
INSTALL NVG FORMATION LIGHT
(Continued)
9-85.2
5.
Position light (5) on doubler (1).
6.
Tighten two screws (7).
Sealant (E336) can irritate skin and
cause burns. Avoid contact with skin,
eyes, or clothing. In case of contact,
immediately flush skin or eyes with
water for at least 15 minutes. Get
medical attention for eyes.
7.
Apply sealant (E336) to two screws (7) and edge
of light (5) at skin.
INSPECT
FOLLOW-ON MAINTENANCE:
Perform operational check (TM 55-1520-240-T).
END OF TASK
9-282