TM 55-1520-240-23-7
9-67
INSTALL SIDE POSITION LIGHT
(Continued)
9-67
Acetone (E20) can form toxic
vapors if exposed to flame. Use in
well-ventilated area, away from open
flame. In case of contact, immediately
flush skin or eyes with water for
at least 15 minutes. Get medical
attention for eyes.
2.
Remove old sealant from access panel. Use
acetone (E20). Wipe with cloth (E120). Use
gloves (E186).
3.
Install light (3) and three screws (4) on panel (5).
Install lamp (6) in light.
4.
Install three washers (7) and nuts (8) on screws
(4).
5.
Disconnect light socket (9).
6.
Insert wire (10) through back of socket (9).
Solder wire to socket. Use solder (E360).
9-229