INSTALL  HEATER FAN  RELAY (Continued)
REMOVE  AVIONICS  COOLING FAN (Continued)

TM-55-1520-240-23-7 CH-47D Heilcopter Manual
Page Navigation
  511    512    513    514    515  516  517    518    519    520    521  
TM  55-1520-240-23-7 9-55 REMOVE  AVIONICS  COOLING  FAN 9-55 INITIAL  SETUP Applicable Configurations: All Tools: Electrical  Repairer’s Tool Kit, NSN  5180-00-323-4915 Materials: Paper  Tags  (E264) Personnel  Required: Aircraft  Electrician Equlpment  Condition: Battery Disconnected  (Task  1-39) Electrical  Power  Off Avionics  Compartment Acoustic  Blanket  Removed (Task  2-208) 1. Tag  and  disconnect five  connectors  (1). 2. Tag  and  disconnect  connector  (2)  from  cooling fan  (3). 9-161