TM  55-1520-240-23-7 9-47 REMOVE  AC  POWER  RECEPTACLE 9-47 INITIAL  SETUP Applicable  Configurations: All Tools: Electrical  Repairer’s  Tool  Kit,  NSN  5180-00-323-4915 Materials: Paper  Tags  (E264) Tape  (E385) Personnel  Required: Aircraft  Electrician Equipment  Condition: Battery  Disconnected  (Task  1-39) Electrical  Power  Off EXT  PWR  DC-AC  Access  Cover  Open  (Task  2-2) 1. Cut  sealant  away  from  eight  screws  (1)  of  ac receptacle  (2). 2. Remove  eight  screws  (1)  from  receptacle  (2). 9-142