TM  55-1520-240-23-7 8-11 TEST  GAS PRODUCER TACHOMETER GENERATOR (Continued) 8-11 5. Adjust  test  set  to  obtain  2500  RPM  (TM 11-6625-673-15-1). 6. Set test  switch  (4)  to  TEST  GEN. 7. Set LOAD  IN  OHMS  switch  (5)  to  40Y.  Check GENERATOR  OUTPUT  VOLTAGE  (6)  by setting TEST  GEN  switch  (7)  to  positions  A-B,  B-C, and  A-C.  Output  voltage  shall  not  exceed  12.5 volts.  Voltage  shall  be  same  at  all  positions (TM 11-6625-673-15-1). 8. Repeat  step  7,  set LOAD  IN  OHMS switch  (5)  to 20Y.  Voltage  shall  not  exceed  12.5  volts  (TM 11-6625-673-15-1). 9. Shut  down  test  set  (2). 10. Shut  down  power  supply  (3). 11. Remove  generator  (1)  from  test  set  (2). FOLLOW-ON  MAINTENANCE: None END  OF  TASK 8-36