ALTERNATING CURRENT (AC) POWER  DISTRIBUTION (Continued) - TM-55-1520-240-23-7_480
ALTERNATING CURRENT (AC) POWER DISTRIBUTION (Continued) APU  GENERATOR OPERATION

TM-55-1520-240-23-7 CH-47D Heilcopter Manual
Page Navigation
  447    448    449    450    451  452  453    454    455    456    457  
TM  55-1520-240-23-7 9-30 ALTERNATING  CURRENT (AC) POWER  DISTRIBUTION (Continued) 9-30 NORMAL OPERATION When  both  main  generator switches  (GEN NO.  1  and GEN  NO.  2) on  the  overhead  ELECT  panel  are  set to  ON,  28 vdc  is  applied  to  each  generator  contactor 241K1  and  241K2  in  the  respective  PDP.  At  the  same time, 28 vdc  from  the  essential  bus is  applied  to  APU generator  contactor  241K3  in  the  No.   2  PDP,  and external  power  contactor 241K5  in  the  No.  1  PDP.  This makes  voltage  available  at  the  crosstie  circuits  so  that if  one  generator fails,  its  bus  will  be  supplied  by  the operating  generator. NO  BREAK  - WORK  HARDER If  either  main  generator  fails  or  is  shut  down,  the associated  NO.  1  or NO. 2  GEN OFF  light on  the  master caution  panel  will  come  on. 9-96