TM  55-1520-240-23-7 9-18 REMOVE  SWITCHED  BATTERY  BUS  RELAY 9-18 INITIAL  SETUP Applicable  Configurations: All Tools: Electrical  Repairer’s Tool  Kit, NSN  5180-00-323-4915 Materials: Paper  Tags  (E264) Tape  (E385) Personnel  Required: Aircraft  Electrician Equipment  Condition: Battery Disconnected  (Task  1-39) Electrical  Power  Off Hydraulic  Power  Off 1. Release  six  fasteners (1)  in  upper  circuit  breaker panel  (2).   Open  panel. 2. Tag  five  wires  (3).   Remove  five  screws  (4)  and lockwashers  (5).   Disconnect  wires.   Use  tags (E264). 3. Tape  exposed  ends  of  wires  (3).   Use  tape (E385). 4. Remove  two  screws  (6),  washers  (7),  and switched  battery  bus  relay  (8). FOLLOW-ON  MAINTENANCE: None END  OF  TASK 9-58