TM 55-1520-240-23-7
8-91
INSTALL FLANGE MOUNTED INSTRUMENTS IN PILOTS OR COPILOTS INSTRUMENT
PANEL
(Continued)
8-91
2.
Check instrument (1). Apply range marks
and index mark to indicator, if required (TM
55-1520-240-10 and TM 55-6600-200-20).
3.
Install packing (3) on fitting body (4) (no packing
on fittings with tapered pipe thread).
4.
Install fitting body (4) in indicator (1).
5.
Check serrated tubing hose (5). Hose connector
(8), nut (7), front ferrule (8), and rear ferrule (9)
must be in place before connecting tubing hose.
8-290