TM 55-1520-240-23-7
8-80.5
TEST AND ADJUST FUEL QUANTITY INDICATOR
(Continued)
8-80.5
59.1.
On test set (17), set RANGE SELECTOR switch
(33) to X10. Set PROBE MMF switch (33.1) to
OFF.
60.
Loosen clamp (34) and turn PROBE knob (35)
of test set (17) until CAPACITANCE INDICATOR
(36) indicates 144.79 mmf. Tighten clamp.
61.
Repeat steps 25 and 26 on test set (18) .
61.1.
Set RANGE SELECTOR switch (39) to X10. Set
PROBE MMF switch (39.1) to 400.
62.
Loosen clamp (40) and turn PROBE knob (41)
of test set (18), until CAPACITANCE INDICATOR
(42) indicates 434.37 mmf. Tighten clamp.
63.
Apply ac electrical power (Task 1-67) .
64.
Close FUEL QTY circuit breaker (5).
8-230