  215    216    217    218    219  220  221    222    223    224    225  
TM  55-1520-240-23-7 8-80.5 TEST  AND ADJUST FUEL QUANTITY  INDICATOR (Continued) 8-80.5 59.1. On  test set  (17),  set RANGE  SELECTOR  switch (33)  to  X10.  Set PROBE  MMF  switch  (33.1) to OFF. 60. Loosen  clamp  (34) and  turn  PROBE  knob  (35) of test set (17)  until  CAPACITANCE  INDICATOR (36)  indicates 144.79  mmf.  Tighten  clamp. 61. Repeat  steps  25  and  26  on  test set  (18) . 61.1. Set RANGE SELECTOR switch  (39) to  X10.  Set PROBE  MMF  switch  (39.1) to  400. 62. Loosen  clamp  (40) and  turn  PROBE  knob  (41) of test set  (18), until  CAPACITANCE  INDICATOR (42)  indicates 434.37  mmf.  Tighten  clamp. 63. Apply ac electrical  power (Task  1-67)  . 64. Close  FUEL  QTY  circuit breaker (5). 8-230