REMOVE  STATIC  PORT ADAPTER (Continued)
INSTALL  STATIC  PORT ADAPTER (Continued)

TM-55-1520-240-23-7 CH-47D Heilcopter Manual
Page Navigation
  101    102    103    104    105  106  107    108    109    110    111  
TM  55-1520-240-23-7 8-34 INSTALL STATIC  PORT ADAPTER 8-34 INITIAL  SETUP Applicable Configurations: All Tools: Aircraft  Mechanic’s Tool  Kit, NSN  5180-00-323-4692 Airframe  Repairer’s Tool Kit, NSN  5180-00-323-4876 Workstand Materials: Dry  Cleaning  Solvent  (E162) Cloths  (E120) Gloves  (E186) Sealant  (E336) Parts: Packing Rivets Personnel  Required: Medium  Helicopter  Repairer Aircraft  Structural  Repairer Inspector References: TM  1-1500-204-23 TM  55-1520-240-23P TM  55-1520-240-T Dry  cleaning  solvent  (E162)  is combustible  and  toxic.  It  can  irritate skin  and  cause  burns.  Use  only  with adequate  ventilation,  away  from  open flame.  In  case  of  contact, immediately flush  skin  or  eyes  with  water  for at  least  15  minutes.   Get  medical attention  for  eyes. NOTE Procedure  is  same  to  install No.  1  or No.  2  static  ports.  No.  1  static port  is shown  here. 1. Clean  mating  surfaces  of  static  port adapter  (1) and  inner  fuselage  skin  (2).  Use  gloves  (E186) and  dry cleaning  solvent  (E162).  Make  sure  no debris  is in  static port holes  (3).  Make  sure  holes are  not  deformed. 8-113