TM  55-1520-240-23-7 9-164.5 ASSEMBLE  FUEL PRE-CHECK  PANEL (Continued) 9-164.5 INSTALL  DIODE NOTE Procedure  is  similar  to  install  eight diodes. 11. Connect  diode  (23) to  terminals  (24).   Observe polarity.  Use  heat sink.  Use  solder  (E319). 12. Remove  tags. INSTALL  INDICATOR  LIGHT NOTE Procedure  is same  to  install  three indicator  lights.   Installation  of  LH REFUEL  VALVE light  is shown  here. 13. Install  lampholder (25),  washer (26),  and  nut (27).   Install  lens  cap  (28). 14. Connect  three  wires (29) by installing  two  screws (30)  and  washers  (31). 9-664