REMOVE  FUEL QUANTITY  INVERTER
REMOVE  FUEL PRE-CHECK PANEL

TM-55-1520-240-23-7 CH-47D Heilcopter Manual
Page Navigation
  997    998    999    1000    1001  1002  1003    1004    1005    1006    1007  
TM  55-1520-240-23-7 9-164.2 INSTALL  FUEL  QUANTITY  INVERTER 9-164.2 INITIAL  SETUP Applicable  Configurations: All Tools: Aircraft Mechanic’s  Tool  Kit,  NSN  5180-00-323-4692 Materials: None Personnel  Required: Medium  Helicopter  Repairer Equipment  Condition: Battery Disconnected  (Task  1-39) Electrical  Power  Off 1. Position  inverter  (1)  on  bracket (2). 2. Install  four  washers  (3)  and  screws  (4). 3. Connect  electrical  connector  (5). FOLLOW-ON  MAINTENANCE: Perform  operational  check  of  single  point  refueling system  (TM  55-1520-240-T). END  OF  TASK 9-652