TM 55-1520-240-23-6
7-260
REMOVE HOOK RELEASE VALVE
(Continued)
7-260
1.
Remove lockwire from electrical plug (1).
2.
Disconnect electrical plug (1) from valve (2).
3.
Tag and disconnect three hydraulic tubes (3).
Use cloths (E135) for spilled fluid. Use gloves
(E186).
4.
Remove two bolts (4) and washers (5) from valve
(2). Remove valve.
5.
Remove reducer (6) and packing (7).
6.
Remove two nipples (8) and packings (9).
FOLLOW-ON MAINTENANCE:
None
END OF TASK
7-953