TM 55-1520-240-23-6
7-202
REMOVE TRANSFER CYLINDER CHECK VALVE
(Continued)
7-202
1.
Remove lockwire from valve (1).
2.
Remove valve (1), four retainers (2), and two
packings (3) from XFR CYL CV port (4). Use
container and cloths (E135) for spilled fluid. Use
gloves (E186).
FOLLOW-ON MAINTENANCE:
None
END OF TASK
7-788