TM 55-1520-240-23-6
7-185
REMOVE APU START MODULE
7-185
INITIAL SETUP
Applicable Configurations:
All
Tools:
Aircraft Mechanics Tool Kit, NSN 5180-00-323-4692
Container, 2 Quart
Materials:
Cloths (E135)
Gloves (E186)
Personnel Required:
Medium Helicopter Repairer
Equipment Condition:
Battery Disconnected (Task 1-39)
Electrical Power Off
Hydraulic Power Off
Cargo Ramp Open and Level (TM 55-1520-240-10)
Utility Hydraulic System Depressurized (Task 7-135.1)
APU Start Module Accumulator Depressurized (Task
1-65)
General Safety Instructions:
Hydraulic fluid (E199) is toxic. It can
irritate skin and cause burns. Avoid
inhaling. Use only with adequate
ventilation. Avoid contact with skin,
eyes, or clothing. In case of contact,
immediately flush skin or eyes with
water for at least 15 minutes. Get
medical attention for eyes.
7-753