INSTALL UTILITY SYSTEM PRESSURE SWITCH
(Continued)
7-167.2
Electrical connectors are to be
tightened no more than 1/16 to
1/8 turn beyond finger-tight during
installation, otherwise they will be
damaged.
1.
Install packing (1) on pressure switch (2). Install
switch. Install connector (3).
2.
Lockwire pressure switch (2) to pilot solenoid
valve (4).
INSPECT
FOLLOW-ON MAINTENANCE:
None
END OF TASK