REMOVE APU START ACCUMULATOR
(Continued)
7-148
Make sure accumulator precharge is
depleted.
NOTE
If a crack in the accumulator is
suspected, refer to TM 1-1520-253-23.
1.
Deleted.
2.
Remove line (2) between accumulator (1) and
fitting (3). Use container and cloths (E135) for
spilled fluid. Use gloves (E186).
3.
Remove two bolts (4) and washers (5) from
mount (6).
4.
Remove accumulator (1). Turn the accumulator
as necessary to clear obstacles. Use container
and cloths (E135) for spilled fluid.
5.
Remove four retainers (7) and two packings (8)
from plate (9).
FOLLOW-ON MAINTENANCE:
None
END OF TASK