TM 55-1520-240-23-6
7-98
TEST PITCH, ROLL, YAW, OR THRUST INTEGRATED LOWER CONTROL ACTUATOR
(ILCA) (AVIM) (Continued)
7-98
TEST 1
GROUND TEST
41.
Check resistance from PIN 7 of the SAS 1 cable
at the electrical unit test set end to the SAS 1
valve body, using ME518 Multimeter. Measure
less than 1 ohm.
NOTE
If resistance exceeds 1 ohm, replace
servo valve or extensible link.
If extensible link is replaced, perform
all extensible link tests.
41.1. Check resistance from PIN 7 of the SAS 2 cable
at the electrical unit test set end to the SAS valve
body, using ME518 Multimeter. Measure less
than 1 ohm.
NOTE
If resistance exceeds 1 ohm, replace
servo valve or extensible link.
If extensible link is replaced, perform
all extensible link tests.
END OF GROUND TEST
FOLLOW-ON MAINTENANCE:
Test 2: No. 1 Extensible Link Self Feedback
Transducer Null Voltage Test (Spare).
7-412
Change 1